VENETIAN BLINDS
Z90 BOX
<

Under plaster (except for Box 5) system of Z90 Box Venetian blinds enables installation on windows and glazing without interfering with the external appearance of the building. The blind’s cover have the form of a box. On the front of the box it is possible to apply plaster which makes the system completely invisible on the facade of the building.

The shape of slats and the possibility of almost complete darkening make the Z90 system the most frequently chosen facade blind system.
<
>
<
>
<

Technical specifications

Blades shape
Z
Maximum width
4.5 m
Maximum height 
3.5 m
Electric drive
Yes
Manual drive
Yes
External application
Yes
Internal application
No
Modular system
No
Blades shape
Maximum sideguide width 
Maximum width
Minimum height
Maximum height 
Maximum projection
Beam height
Tilt angle
Electric drive
Manual drive
External application
Internal application
Cassette
Optional hood
Cover
Fabric
Valance
Rollo Volant
Optional tilt angle adjustment
Modular system
Available colours
Minimum height
Optional overlapping arms
Telescopic front bar supports
Fixed projection
Fixed width
Fixed clear height
Blade spacing
Blade rotation angle
Water drainage system
Blades shape
Maximum sideguide width 
Maximum width
Minimum height
Maximum height 
Maximum projection
Beam height
Tilt angle
Electric drive
Manual drive
External application
Internal application
Cassette
Optional hood
Cover
Fabric
Valance
Rollo Volant
Optional tilt angle adjustment
Modular system
Available colours
Minimum height
Optional overlapping arms
Telescopic front bar supports
Fixed projection
Fixed width
Fixed clear height
Blade spacing
Blade rotation angle
Water drainage system
Selt Standard colors

Drive in
Z90 Box system

Electric
drive
Electric
drive
The electric motor is the most popular and convenient way to control Venetian blinds. Apart from the convenience of control, it allows you to connect the blind to the Smart Home system and to use additional accessories, such as a wind sensor or a sun sensor. The blind can be operated with a switch on the wall or remotely – by using a remote control.

Type
of slats

Z-shaped slat
The form of these slats resembles the letter Z and has been designed in such a way as to ensure maximum darkening of the room. Their shape also guarantees a very low bundle height, which is important in places where there is a limited space for installation.

Type
of cassette

All cassettes are made of extruded aluminium (Box 1 and 2 only partially). Their extension and plaster carrier can be painted in any colour available in RAL collection.
Cassettes differ from each other not only in size, but above all in the purpose of the assembly, the type of which is crucial in choosing the right Box system.
BOX 1
A - Window frame
B - Lintel

-Available in 4 box heights:
220 mm, 270 mm, 310 mm, 350 mm
-Revision lid enables easy installation.
-Cassette partially made of extruded aluminium with a wall thickness of 2mm.
-Painting in any colour from RAL palette
BOX 1 NEW
A - Window frame
B - Lintel
 
- Available in 5 box heights: 220mm, 280mm, 350mm, 400mm*, 460mm* (Width max. 3,5m)
- Revision cover enables easy installation
- Cassette made entirely of extruded aluminium with wall thickness of 2,22 mm
BOX 2
AB - Window frame and lintel
C - Styrodur

-Available in 4 box heights: 220 mm, 270 mm, 310 mm, 350 mm.
 -Revision lid enables easy installation.
-Cassette partially made of extruded aluminium with a wall thickness of 2mm.
-Painting in any colour from RAL palette.
-Variant with lintel insulation.
BOX 2 NEW
AB - Window frame and lintel
C - Styrodur

- Available in 5 box heights: 220mm, 280mm, 350mm, 400mm*, 460mm* (Width max. 3,5m)
- Revision cover enables easy installation
- Cassette made entirely of extruded aluminium with wall thickness of 2,22 mm
- Variant with lintel insulation
BOX 3
A - Window frame
B - Lintel

-Available in 4 box heights: 220 mm, 270 mm, 310 mm, 350 mm.
 -Cassette partially made of extruded aluminium with wall thickness of 3mm or 4mm.
-Facilitated application of the insulation layer.
-Painting in any colour from RAL palette.
BOX 4
AB - Window frame and lintel
C - Styrodur

-Available in 4 box heights: 220 mm, 270 mm, 310 mm, 350 mm.
-Cassette partially made of extruded aluminium with a wall thickness of 3mm or 4mm.
 -Facilitated application of the insulation layer.
- Painting in any colour from RAL palette.
 -Variant with lintel insulation.
BOX 5
A - Window frame
B - Lintel

 - Available in 4 box heights: 220 mm, 270 mm, 310 mm, 350 mm. 
- Cassette partially made of extruded aluminium with a wall thickness of 3mm or 4mm. 
- Fully painted surface-mounted cassette
BOX 1, 1 NEW, 3
See more
BOX 2, 2 NEW, 4
See more
BOX 5
See more

Features of
Z90 Box system

01 / 06
Under plaster
installation
Cassettes are hidden under the plaster which makes this solution practical and aesthetic.
<
>
02 / 06
Easy
access
The under-enaster box is equipped with revision lid which enables easy installation and servicing of the blinds.
<
>
03 / 06
Choice of possible
installation options
In Z90 Box system you can choose between several types of Box cassettes depending on the type of building. Box type 2 and 4 have additional lintel insulation made of styrodur.
<
>
04 / 06
Greater shading
The design of Z90 slats provides greater tightness and thus effective and greater shading.
<
>
05 / 06
Compact size
when rolled up
The shape of the slats and the ladder technology make it possible to reduce the bundle height.
<
>
06 / 06
Perfected details
The meticulously crafted design ensures a longer service life for components, such as lifting tapes and ladders.
<
>
AUTOMATION
SMART HOME
QUIET SYSTEM OPERATION
EASY ASSEMBLY
PREMIUM QUALITY
PROTECTION AGAINST SUN
NATURAL AIR CONDITIONING
Find your
inspiration!

In the gallery you will find selected projects based on Selt systems, presenting their functions and variety of uses.

Get inspired and choose a solution tailored to the needs of your home or investment.
<
>

Watch
the assembly video

Frequently
asked questions

Can the blinds be cleaned with water?
It is recommended to clean small dirt on metal/aluminium surfaces with water and mild cleaning agents. It is unacceptable to use a pressure washer as well as strong cleaning agents and solvents, e.g. alcohol or gasoline. It is forbidden to use cleaning agents with the addition of chlorine, ammonia, kerosene, acetone and bleach to clean the system as well as to use such products in the vicinity of the system as this increases the risk of corrosion.
Does the color of the slats fade when exposed to sunlight?
Our blinds are made of the highest quality materials, using colour protection technologies. As a result, the colour of the blinds even when exposed to constant sunlight, does not lose its intensity.
How to measure the blinds installed in the niche yourself?
If the blind is mounted in a niche, the width should be measured in three places: at the top, in the middle and at the bottom. The smallest of these dimensions is given as the total dimension. In the case of system with cable guides it must be remembered that the width of the slats is always 2 cm smaller than the total width. As for the height, the total size of the niche should be given. Please note that depending on the height of the window frame, the system’s bundle may overlap the window light! The height of the blind’s bundle always depends on the total height of the system.

Files to download

212---katalogi
pdf
Catalogue
Catalogue
pdf
Portfolio
Portfolio
pdf
About SELT
About SELT
pdf
Fabrics-Slat-Construction colours
Fabrics-Slat-Construction colours
268---ulotki
213---ArkuszeZamowien
---cenniki
---suplementy
217---dte
pdf
Technical & installation document Z90
Technical & installation document Z90
218---dwu
219---deklaracje_z
265---owsowg
---Naprawa_odpłatna
---b2b_warunki
---b2b_informacje
Selt@2022 All rights reserved
Zapisano